<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	 xmlns:media="http://search.yahoo.com/mrss/" >

<channel>
	<title>havalandırma &#8211; Trakya Laboratuvar</title>
	<atom:link href="https://www.trakyalaboratuvar.com.tr/e/havalandirma/feed" rel="self" type="application/rss+xml" />
	<link>https://www.trakyalaboratuvar.com.tr</link>
	<description></description>
	<lastBuildDate>Thu, 21 Jan 2021 14:39:29 +0000</lastBuildDate>
	<language>tr</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1</generator>
	<item>
		<title>Havalandırma ve Klima Tesisatı Periyodik Muayenesi</title>
		<link>https://www.trakyalaboratuvar.com.tr/havalandirma-ve-klima-tesisati-periyodik-muayenesi</link>
					<comments>https://www.trakyalaboratuvar.com.tr/havalandirma-ve-klima-tesisati-periyodik-muayenesi#respond</comments>
		
		<dc:creator><![CDATA[hosteva]]></dc:creator>
		<pubDate>Thu, 18 Jun 2020 13:59:16 +0000</pubDate>
				<category><![CDATA[Periyodik Kontrol]]></category>
		<category><![CDATA[havalandırma]]></category>
		<category><![CDATA[klima]]></category>
		<category><![CDATA[periyodik muayene]]></category>
		<category><![CDATA[tesisat]]></category>
		<guid isPermaLink="false">https://www.trakyalaboratuvar.com.tr/?p=159</guid>

					<description><![CDATA[<p>Havalandırma tesisatı, tesis içerisinde havanın şartlandırılması, temiz hava sağlanması veya üretim/proses sonucu oluşan kirli havanın çalışanlara ulaşmadan ortamdan uzaklaştırılması için kullanılmaktadır. Havalandırma ve klima tesisatı periyodik muayenesi ve kontrolü, tesis güvenliği açısından çok büyük öneme sahiptir. İş Ekipmanlarının Kullanımında Sağlık ve Güvenlik Şartları Yönetmeliği gereğince, yılda en az bir kez muayene ve kontrollerinin yapılması zorunlu [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.trakyalaboratuvar.com.tr/havalandirma-ve-klima-tesisati-periyodik-muayenesi">Havalandırma ve Klima Tesisatı Periyodik Muayenesi</a> first appeared on <a rel="nofollow" href="https://www.trakyalaboratuvar.com.tr">Trakya Laboratuvar</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Havalandırma tesisatı, tesis içerisinde havanın şartlandırılması, temiz hava sağlanması veya üretim/proses sonucu oluşan kirli havanın çalışanlara ulaşmadan ortamdan uzaklaştırılması için kullanılmaktadır.</p>
<p>Havalandırma ve klima tesisatı periyodik muayenesi ve kontrolü, tesis güvenliği açısından çok büyük öneme sahiptir. İş Ekipmanlarının Kullanımında Sağlık ve Güvenlik Şartları Yönetmeliği gereğince, yılda en az bir kez muayene ve kontrollerinin yapılması zorunlu hale getirilmiştir. Yine İşyeri Bina ve Eklentilerinde Alınacak Sağlık ve</p>
<p>Güvenlik Önlemlerine İlişkin Yönetmelik kapsamında kayıtlarının tutulması gerekmektedir.</p>
<p>Havalandırma ve klima tesisatı kontrollerinde tesise ait havalandırma projelerinin kurulmuş olan sistem ile uygunluğunun kontrolü, temiz hava debisinin ölçümü, menfez kontrolü,.. vb. çok sayıda parametrede ölçüm ve kontroller gerçekleştirilerek raporlanmaktadır.</p>
<p>Trakya Laboratuvar olarak periyodik muayene ve İSG ölçümleri alanında TÜRKAK tan akredite olan laboratuvarımız hem mekanik anlamdaki bilgi birikimi hem de termal konfor cihazı ile yapmış olduğumuz hava akım hızı ölçümü ile, havalandırma ve klima tesisatı periyodik kontollerini yerine getirmektedir.</p>
<p>Havalandırma tesisatı kontrolü yapılırken öncelikli olarak havalandırma tesisatı projesi esas alınır. Fakat bölgemizde bulunan işletmelerin maalesef % 90 ına yakınında havalandırma tesisatı projesine rastlanılmamaktadır. Yaptığımız ölçümlerde fan değerleri ile ölçülen debi karşılaştırılarak tesisatın uygunluğu kontrol edilir. Fandan dağılan hava akımının her bir menfezdeki kontrolü tek tek yapılır ve tesisat bağlantılarının uygunluğu kontrol edilir.</p>
<p>Son yıllarda yapılan denetlemeler sonucu firmalardan havalandırma yeterlilik raporu istenmektedir. Havalandırma yeterliliği işletme doğal ve/veya yapay şekilde bulunan havalandırmanın işletmede çalışan kişi sayısı ve havalandırmanın ölçümü yapılacak olan bölümün hacmi dikkate alınarak doğal ve/veya yapay havalandırma vasıtasıyla oluşturulan debininde hesaba katılarak bulunan değerin standartlarda belirtilen değerlerin üstünde olup olmadığını kontrol etmektir. Bu kontrollerde mevcut havalandırma tesisatı varsa fanın debi kontrolü yapılır. Ayrıca işletmede bulunan kapı pencere havalandırma kapaklarının alanı hesaplanarak buralardan işletmede oluşan hava akım hızı da ölçülerek debi hesabı yapılır. Bu hesabın yeterlilik kontrolü yapılacak bölümün hacmine bölünmesiyle saatteki hava değimi sayısı hesaplanır. Bulunan bu değer firmaların faaliyet alanına göre farklılık göstermektedir.</p>
<table width="100%">
<tbody>
<tr>
<td width="56%"><b><strong>MAHAL CİNSİ</strong></b></td>
<td width="43%"><b><strong>SAATTE HAVA  DEĞİŞİM SAYISI</strong></b></td>
</tr>
<tr>
<td width="56%">Fırın Atölyeleri ( Ergitme Ve Isıl İşlem  Fırınları )</td>
<td width="43%">30 – 60</td>
</tr>
<tr>
<td width="56%">Boya Atölyeleri</td>
<td width="43%">30 – 60</td>
</tr>
<tr>
<td width="56%">İşleme Atölyeleri</td>
<td width="43%">6 – 10</td>
</tr>
<tr>
<td width="56%">Bankalar</td>
<td width="43%">2 – 4</td>
</tr>
<tr>
<td width="56%">Otel Barları</td>
<td width="43%">4 – 6</td>
</tr>
<tr>
<td width="56%">Çamaşırhaneler</td>
<td width="43%">20 – 30</td>
</tr>
<tr>
<td width="56%">Fırınlar</td>
<td width="43%">20 – 30</td>
</tr>
<tr>
<td width="56%">Bürolar (*)</td>
<td width="43%">4 – 6</td>
</tr>
<tr>
<td width="56%">Kafeterya Ve Kafeterya Barları</td>
<td width="43%">10 – 12</td>
</tr>
<tr>
<td width="56%">Kargo Ambarları ( Genel )</td>
<td width="43%">6 – 10</td>
</tr>
<tr>
<td width="56%">Et , Yumurta, V.S Cinsinden Yiyecek Taşıyan Gemi Ambarı</td>
<td width="43%">10 – 20</td>
</tr>
<tr>
<td width="56%">Kantinler</td>
<td width="43%">4 – 6</td>
</tr>
<tr>
<td width="56%">Fotoğraf Stüdyolarındaki Karanlık Odalar</td>
<td width="43%">10 – 15</td>
</tr>
<tr>
<td width="56%">Mantarhaneler ( Mantar Yetiştirilen Mahaller )</td>
<td width="43%">10 – 20</td>
</tr>
<tr>
<td width="56%">Sinemalar (*)</td>
<td width="43%">10 – 15</td>
</tr>
<tr>
<td width="56%">Ticari Mutfaklar Veya Okul Mutfakları</td>
<td width="43%">15 – 20</td>
</tr>
<tr>
<td width="56%">Ev Mutfakları</td>
<td width="43%">10 – 15</td>
</tr>
<tr>
<td width="56%">Kliseler</td>
<td width="43%">½ – 1</td>
</tr>
<tr>
<td width="56%">Fabrikalar ( Genel )</td>
<td width="43%">6 – 10</td>
</tr>
<tr>
<td width="56%">Dökümhaneler</td>
<td width="43%">20 – 30</td>
</tr>
<tr>
<td width="56%">Gemilerde Meyva Ambarları</td>
<td width="43%">20 – 30</td>
</tr>
<tr>
<td width="56%">Garajlar ( Oto Tamirhaneleri )</td>
<td width="43%">6 – 8</td>
</tr>
<tr>
<td width="56%">Toplantı Salonları (*)</td>
<td width="43%">4 – 6</td>
</tr>
<tr>
<td width="56%">Hastahaneler</td>
<td width="43%">4 – 6</td>
</tr>
<tr>
<td width="56%">Laboratuarlar</td>
<td width="43%">4 – 6</td>
</tr>
<tr>
<td width="56%">Lavabolar</td>
<td width="43%">10 – 15</td>
</tr>
<tr>
<td width="56%">Yüzme Havuzları</td>
<td width="43%">20 – 30</td>
</tr>
<tr>
<td width="56%">Domuzhaneler</td>
<td width="43%">6 – 10</td>
</tr>
<tr>
<td width="56%">Kümeshaneler</td>
<td width="43%">6 – 10</td>
</tr>
<tr>
<td width="56%">Konut Mahalleri</td>
<td width="43%">1 – 2</td>
</tr>
<tr>
<td width="56%">Lokantalar</td>
<td width="43%">6 – 10</td>
</tr>
<tr>
<td width="56%">Ziyafet Salonları</td>
<td width="43%">6 – 10</td>
</tr>
<tr>
<td width="56%">Bilardo Salonları</td>
<td width="43%">6 – 8</td>
</tr>
<tr>
<td width="56%">Kazan Daireleri</td>
<td width="43%">20 – 30</td>
</tr>
<tr>
<td width="56%">Sınıflar</td>
<td width="43%">2 – 3</td>
</tr>
<tr>
<td width="56%">Klüp Salonları</td>
<td width="43%">8 – 10</td>
</tr>
<tr>
<td width="56%">Dans Salonları (*)</td>
<td width="43%">6 – 8</td>
</tr>
<tr>
<td width="56%">Makina Daireleri</td>
<td width="43%">20 &#8211; 30</td>
</tr>
<tr>
<td width="56%">Gemilerde Dinlenme Salonları</td>
<td width="43%">10 – 20</td>
</tr>
<tr>
<td width="56%">Boyahaneler</td>
<td width="43%">30 &#8211; 60</td>
</tr>
<tr>
<td width="56%">Tiyatrolar (*)</td>
<td width="43%">10 – 15</td>
</tr>
</tbody>
</table>
<p>The post <a rel="nofollow" href="https://www.trakyalaboratuvar.com.tr/havalandirma-ve-klima-tesisati-periyodik-muayenesi">Havalandırma ve Klima Tesisatı Periyodik Muayenesi</a> first appeared on <a rel="nofollow" href="https://www.trakyalaboratuvar.com.tr">Trakya Laboratuvar</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.trakyalaboratuvar.com.tr/havalandirma-ve-klima-tesisati-periyodik-muayenesi/feed</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Havalandırma Tesisatı Muayenesi</title>
		<link>https://www.trakyalaboratuvar.com.tr/hizmet/havalandirma-tesisati-muayenesi</link>
		
		<dc:creator><![CDATA[hosteva]]></dc:creator>
		<pubDate>Tue, 16 Jun 2020 15:51:50 +0000</pubDate>
				<category><![CDATA[akım]]></category>
		<category><![CDATA[hava]]></category>
		<category><![CDATA[havalandırma]]></category>
		<category><![CDATA[havalandırma muayenesi]]></category>
		<category><![CDATA[havalandırma periyodik]]></category>
		<category><![CDATA[havalandırma tesisatı]]></category>
		<category><![CDATA[isgüm]]></category>
		<category><![CDATA[nasıl yapılır]]></category>
		<category><![CDATA[ölçüm]]></category>
		<category><![CDATA[onaylı laboratuvar]]></category>
		<category><![CDATA[periyodik kontrol]]></category>
		<category><![CDATA[periyodik muayene]]></category>
		<category><![CDATA[periyodik muayenesi]]></category>
		<category><![CDATA[rapor]]></category>
		<category><![CDATA[tesisat]]></category>
		<category><![CDATA[test]]></category>
		<category><![CDATA[türkak]]></category>
		<guid isPermaLink="false">https://www.trakyalaboratuvar.com.tr/?post_type=hizmet&#038;p=40</guid>

					<description><![CDATA[<p>Havalandırma Tesisatı Muayenesi Çalışanların maruz kaldığı toz, gaz ve kimyasal maruziyetlere karşı yeterli bir havalandırma ile sağlık ve güvenliklerini sağlayabiliriz. Bunun için iyi bir havalandırma tesisatı kurmalı ve kurulan bu sistemin de periyodik olarak muayene edilmesi yada diğer deyişle periyodik kontrol yapılması şarttır. Yapılan çoğu havalandırma tesisatı bilinçsizce yapılmakta ve yeterli bir havalandırma olup olmadığı [&#8230;]</p>
<p>The post <a rel="nofollow" href="https://www.trakyalaboratuvar.com.tr/hizmet/havalandirma-tesisati-muayenesi">Havalandırma Tesisatı Muayenesi</a> first appeared on <a rel="nofollow" href="https://www.trakyalaboratuvar.com.tr">Trakya Laboratuvar</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><em><img fetchpriority="high" decoding="async" class="alignright wp-image-490" src="https://www.trakyalaboratuvar.com.tr/wp-content/uploads/2020/06/havalandirma-tesisati-muayenesi-2.jpg" alt="Havalandırma Tesisatı Muayenesi" width="500" height="500" title="Havalandırma Tesisatı Muayenesi 2" srcset="https://www.trakyalaboratuvar.com.tr/wp-content/uploads/2020/06/havalandirma-tesisati-muayenesi-2.jpg 600w, https://www.trakyalaboratuvar.com.tr/wp-content/uploads/2020/06/havalandirma-tesisati-muayenesi-2-300x300.jpg 300w, https://www.trakyalaboratuvar.com.tr/wp-content/uploads/2020/06/havalandirma-tesisati-muayenesi-2-150x150.jpg 150w" sizes="(max-width: 500px) 100vw, 500px" />Havalandırma Tesisatı Muayenesi</em></p>
<p>Çalışanların maruz kaldığı toz, gaz ve kimyasal maruziyetlere karşı yeterli bir havalandırma ile sağlık ve güvenliklerini sağlayabiliriz. Bunun için iyi bir havalandırma tesisatı kurmalı ve kurulan bu sistemin de periyodik olarak muayene edilmesi yada diğer deyişle periyodik kontrol yapılması şarttır.</p>
<p>Yapılan çoğu havalandırma tesisatı bilinçsizce yapılmakta ve yeterli bir havalandırma olup olmadığı kontrol edilmemektedir. Oysaki çalışanların ihtiyaç duyduğu oksijen miktarı ve hava değişim sayısını hesaplanarak uygun bir havalandırma tesis edilebilir.</p>
<p><strong>Trakya Laboratuvar</strong> olarak öncelikle Havalandırma Yeterlilik raporu hazırlamakta ve sonrasında ise tesisatı hesaplamalar ile muayene etmekteyiz.</p>
<h2 id='havalandırma-tesisatı-muayenesi'  id="boomdevs_1">Havalandırma Tesisatı Muayenesi</h2>
<p>Gerek periyodik kontrol yönetmeliği gerekse iş müfettişlerinin, İş Güvenliği Uzmanlarından beklentisi bu yönde olmakta ve denetlemelerde bu durum sorgulanmaktadır.</p>
<p><a href="https://www.trakyalaboratuvar.com.tr/">Trakya Laboratuvar</a> İSGÜM onaylı laboratuvar ve TÜRKAK onaylı hava akım hızı ölçüm yetkisi ile bu raporlarla ilgili bilgi ve ölçüm tecrübeleri ile gerekli desteği doğru bir şekilde vermekte ve çalışanların sağlık ve güvenliklerini sağlamaya çalışmaktadır.</p>
<table style="height: 317px;" width="730">
<tbody>
<tr>
<td width="221"><b><strong>PMAN ADI</strong></b></td>
<td width="126"><b><strong>KONTROL PERİYODU</strong></b></p>
<p><b><strong>(Azami Süre)</strong></b></p>
<p><b><strong> </strong></b></p>
<p>(İlgili standardın ön-gördüğü süreler saklı kalmak koşulu ile)</td>
<td width="310"><b><strong> </strong></b></p>
<p><b><strong>PERİYODİK KONTROL KRİTERLERİ</strong></b></p>
<p><b><strong> </strong></b></p>
<p>(İlgili standartlar aşağıda belirtilmiştir.)**</td>
</tr>
</tbody>
</table>
<table style="height: 90px;" width="727">
<tbody>
<tr>
<td width="221">Havalandırma ve Klima Tesisatı</td>
<td width="126">1 Yıl</td>
<td width="310">Projede belirtilen kriterlere uygun olup olmadığının belirlenmesine y</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>The post <a rel="nofollow" href="https://www.trakyalaboratuvar.com.tr/hizmet/havalandirma-tesisati-muayenesi">Havalandırma Tesisatı Muayenesi</a> first appeared on <a rel="nofollow" href="https://www.trakyalaboratuvar.com.tr">Trakya Laboratuvar</a>.</p>